ÀüÀÚµ¿ CO2 ÀÎÅ¥º£ÀÌÅÍ, ¿¡¾î ÀÚÄÏ, Á÷Á¢ °¡¿ ¹æ½Ä, Dual Decontamination Cycles, HEPA Filter System,
Air-jacketed Automatic CO2 Incubators with Decontamination Cycles, DHD AutoFlow 5510, 188L |
°¡°Ý : °ßÀû°¡
Á¦Á¶»ç : Nuaire
¸ðµ¨¼±Åà : ÃÑ (2)°³ÀÇ ¸ðµ¨ÀÌ µî·ÏµÇ¾î ÀÖ½À´Ï´Ù.

|
|
|
 |
Origin : Made in USA (¹Ì±¹) * NuAire Quality Statements (ǰÁú º¸Àå ÀÎÁõ) : ISO 9001:2000 Certificate (ǰÁú°æ¿µ½Ã½ºÅÛ ±¹Á¦±Ô°Ý ÀÎÁõ) ISO 13485 Certificate (ÀÇ·á±â±â ÀÎÁõ)
* Class 100 Air Flow Within the Chamber * Dual Temperature Sensor Probe & Digital Infrared CO2 Gas Sensor * Replaceable HEPA Filter * Direct Heat with Sterilization (Dual Decontamination Cycles)
Application/»ç¿ëºÐ¾ß * ¸ðµç ¼¼Æ÷ ¹× Á¶Á÷ ¹è¾ç °ü·Ã ¿¬±¸ * ¿À¿°¹°Áú ¹ÝÀÔÀÌ ½¬¿î ¼¼Æ÷ ¹è¾ç ¿¬±¸ * Storage and Preservation of Embryos, Gametes and Animal Tissue Cell Cultures at on near body Temperature. * in vitro Fertilization, Genetic Disease, Cancer Research etc. * Microbial Organism (Mycoplasma, Chlamydia etc.) Control
Features/Ư¡ * Class 100 Air Flow Within the Chamber : HEPA ÇÊÅÍ´Â ¸Å 1ºÐ °£°ÝÀ¸·Î è¹ö ³» °ø±â¸¦ ¿ÏÀü ¼øÈ¯½ÃÄÑ * è¹ö ³»ÀÇ °ø±â¸¦ ûÁ¤ »óÅ·ΠÁö¼Ó À¯Áö * Dual Temperature Sensor Probe & Digital Infrared CO2 Gas Sensor * Replaceable HEPA Filter * è¹ö ¿À¿°½Ã µÎ °¡Áö (95¡É Humidified Decontamination Cycle or 145¡É Dry Decontamination Cycle) ¼Òµ¶ »çÀÌŬÀ» ÀÌ¿ëÇÏ¿© ¸ê±Õ * ºñºÐ»ê Àû¿Ü¼± CO2 ¼¾¼ ä¿ëÀ¸·Î ¸Å¿ì ¾ÈÁ¤Çϰí ÀæÀº º¸Á¤ÀÌ ÇÊ¿ä ¾ø´Â ÃøÁ¤À¸·Î è¹ö ³» Á¤È®ÇÑ CO2 Á¶ÀýÀÌ °¡´É * ±³Ã¼°¡ ¿ëÀÌÇÑ ´ëÇü HEPA ÇÊÅÍ Ä«Æ®¸®Áö´Â ¼øÈ¯ ½Ã °ø±â¸¦ ¿©°úÇÏ¿© è¹ö ³»ºÎ ȯ°æÀ» ûÁ¤À¸·Î À¯Áö * Fan°ú Blower¸¦ ÅëÇÑ Ã¨¹ö ³»ºÎ °ø±â´Â ¸Å¿ì ´À¸° ¼Óµµ·Î ±ÕÀÏÇÏ°Ô ¼øÈ¯µÇ¸ç ¼¼Æ÷ ¼ºÀå¿¡ ¿µÇâÀ» ¹ÌÄ¡Áö ¾ÊÀ½ * ÀæÀº ¹® ¿©´ÝÀÌ¿¡µµ è¹ö ³»ºÎ´Â ºÐ´ç 0.3¡ÉÀÇ ¼Óµµ·Î ¿Âµµ º¸»óµÇ¸ç, ½Ã·á¿¡ ¿ÂµµÀÇ ¿µÇâÀ» ÃÖ¼ÒÈ ÇÔ * Microprocessor Based, Non-Dispersive Infrared CO2 Sensor is within the Chamber Air Plenum so very Accurate CO2 control is achieved. * The Microprocessor is "User-Friendly" with Status Indicators, LED Display of Control Parameters and a Touch Control Keypad to permit Efficient Operator entry of Data. * Directly Heated by Foil Heating Elements attached to the Sides, Bottom, Top and Back of the Chamber * Constant Air Circulating within the Chamber using a Continuous Operating Fan / Motor / Blower within the Upper Air Plenum and Sidewall Duct System * Continued Air Filtration in the chamber using a Large Replaceable 99.99% Efficient HEPA Filter Cartridge * HEPA Filter is made for Decontamination Cycle Temperatures. * The HEPA Filter Uniformly distributes and cleans the Air within the Chamber at a rate of one Complete Change per Minute. * Relative Humidity Level up to 95% is achieved in the Incubator by the Use of a Stainless Steel Pan filled with Distilled Water and Placed on the Bottom of the Chamber. * An Air Pump Continuously Introduces Fresh Air into the Chamber at a Variable Rate to Reduce Condensation. * Reliable, Accurate, Stable Temperature and Infrared Gas Controls with Quality and Value to meet Laboratory Performance for Optimum Growth Conditions * The Interior Corners of the Growth Chamber are Coved for Ease of Cleaning and to prevent Contaminants from becoming Trapped. * All Stainless steel Shelves, Shelf Supports, Guide Rails, and Air Plenum are easily Removable for Cleaning * A Microprocessor Controlled Air Pump Injects Air at User Settable Intervals to control Condensation. * The incubator is programmed with options that give the user control of System use, CO2 sensor calibration procedures, alarm parameters, & adaptation to different lab environments.
Direct Heat Sterilization (Dual Decontamination Cycles) * 95¡É Humidified Decontamination Cycle Eradicates Contaminating Agents.Complete Cycle Takes 14 Hours to Run * 145¡É High Temperature Dry Decontamination Cycle Eradicates Contaminating Agents. Complete Cycle |
 |
|
|