Á¦Ç°Á¤º¸
°í°´¼¾ÅÍ
ÀÚÁÖ¹¯´ÂÁú¹® ä¿ë°ø°í
»ç¿ë¼³¸í¼­ A/SÁ¢¼ö
½ÇÇè±âÀÚÀç(ÃÊÀÚ·ù) A~K Ȩ > Á¦Ç°Á¤º¸ > ½ÇÇè±âÀÚÀç(ÃÊÀÚ·ù) A~K > Balances : Àú¿ï > Moisture Analyzer : ¼öºÐÃøÁ¤¿ë

ÃÊÁ¤¹Ð/´Ù¿ëµµ ¼öºÐÃøÁ¤±â, ÀüÀÚµ¿-digital, 3¡¿displays 0~100%(0.01) / 50~160¡É / 1sec~9.50h, FDA / GLP / ISO

High-standard Moisture Analyzer, MLB(R), Precise/Multi-use,1mg~50g / 0.01~100% with Fully auto-digit

°¡°Ý : °ßÀû°¡
Á¦Á¶»ç : KERN

¸ðµ¨¼±Åà : ÃÑ (6)°³ÀÇ ¸ðµ¨ÀÌ µî·ÏµÇ¾î ÀÖ½À´Ï´Ù.
Àüü¸ðµ¨ ¹× »ç¾çº¸±â

¸ñ·Ïº¸±â
Á¦Ç°»ó¼¼¼³¸í
* Multi-use in 1mg ~ 50g
  ¡°Real Application Table¡±
 -ÃÊÁ¤¹Ð / ´Ù¿ëµµ (0.001 ~ 50 g) :
   ºÐ¾ßº° ´Ù¾çÇÑ ½Ã·á¿¡ ´ëÇÑ
   ÃøÁ¤¹ý Á¦°ø.
 -ƯÈ÷ ½Äǰ, ÀǾàǰ, È­ÇÐ, µµ·á,
   ³ó¾÷, ºÐü»ê¾÷ºÐ¾ß¿¡ ÀûÇÕ.
* ÀüÀÚµ¿, 3°³ÀÇ Digital Ç¥½Ãâ :
 -°ÇÁ¶»óÅÂ(%/g)
 -¿Âµµ(¡É)
 -½Ã°£(sec. ~ h.)
* ¡°Ext-CAL¡± program :
   ½Å¼Ó/°£ÆíÇÑ Calibration
   (by external test, Ç¥Áغе¿Àº º°µµ)
* 3¡¿Displays after drying :
  - % Humidity : °¨¼ÒµÈ ¾×ü¹«°Ô
                       0~100%
  - % Dry mass : ³²Àº °íü¹«°Ô
                       100%~0%
  - % ¡°ATRO¡± : 100 ~ 999%
* ¡°Drying-sequence¡± and
   ¡°Switch-Off criteria¡± : PDFÆÄÀÏÂüÁ¶!
* 10¡¿Sample dish (Al. ¥Õ 92 mm)
   Æ÷ÇÔ.
* Date-interface RS232C ³»Àå.

   Printer 911.013� or PC ¿¬°á¿ë

ÁÖ¿ä ±Ô°Ý (Specifications)
1mg ~ 50g ½Ã·á¹«°Ô(PDFÆÄÀÏÂüÁ¶)
0 ~ 100% ½Àµµ (0.01% : PDFÆÄÀÏÂüÁ¶)
¿Âµµ / Heater Á¶Àý½Ä :
 - 50 ~ 160¡É, 1¡É readout
 - 2¡¿Quartz halogen heater.
   2¡¿200W = 400 watts.
Time : 1 sec. ~ 9.50 h. (PDFÆÄÀÏÂüÁ¶)
Size 17¡¿30¡¿h18 cm, 5kg ¹«°Ô
±â´É Ãß°¡¿ë Options :
  (1) MLB.A01� Al. Sample dish
       spare¿ë, ¥Õ92 mm, 80 pcs/Pk.
  (2) MLB.A03� ¿Âµµ Calibration-set :
       Á¤¹Ð¿ë. ¿ÂµµÃøÁ¤ Sensor Æ÷ÇÔ.
  (3) RH.A02� round fiberglass filter :
       °¡¿­°ÇÁ¶½Ã Æ¢¾î(Splash) ³ª°¡°Å
       ³ª Ç¥¸é¿¡ ÇǸ·ÀÌ Çü¼ºµÇ´Â
       ½Ã·á¸¦ À§ÇÑ Æ¯¼ö±¸Á¶ÀÇ µÕ±Ù
       ÇÊÅÍÀÓ. 80ea/Pk.
  (4) Standard Printer YKB.01
       RS232C & Æø 11 cm ÀμâÁö Æ÷ÇÔ.
     - ¼³¸íÀº ÈĹÌÀÇ¡°Access.¶õ¡±ÂüÁ¶!
¡Ø º¸´Ù ÀÚ¼¼ÇÑ ±Ô°ÝÀº : PDFÆÄÀÏÂüÁ¶

ÁÖ¹® (Ordering)
KE.MLB50.3N     Moisture analyzer MLB50.3N(R), 0.01~100% / 1mg~50g
Options for Additional Functions
KE.MLB.A01     (1) Spare Sample dish, ¥Õ92 mm Al.
KE.MLB.A03     (2) ¿Âµµ Calibration-set, Á¤¹Ð¿ë ¿ÂµµÃøÁ¤¼¾¼­ Æ÷ÇÔ.
KE.RH.A02       (3) Round Fibreglass-filter, PDFÆÄÀÏÂüÁ¶
KE.YKB.01       Standard Printer, size 16¡¿14¡¿5cm, Æø 112cm, Paper ¿Í RS232C Æ÷ÇÔ.
                       ¹Ù¶õ½º¿Í ÇÔ²² ±¸¸Å½Ã ¿¬°á Interface Cable(KE.MLB.A05) ¹«·áÁõÁ¤
KE.MLB.A05     Interface Cable, ±æÀÌ 1.5m, for MLB-Model
¸ðµ¨ ¹× »ç¾ç
Cat. No. ¸ðµ¨¸í ´Ü À§ °¡ °Ý ¼ö·® ¼± ÅÃ
KE.MLB.A01 Balance plate, aluminium, ¥Õ92mm, 80/Pk. °ßÀû°¡ °ßÀû¹®ÀÇ
KE.MLB.A03 Balance calibration set, temperature, 1/Ea. °ßÀû°¡ °ßÀû¹®ÀÇ
KE.MLB.A05 Cable, for printer, for mlb model, 1/Ea. °ßÀû°¡ °ßÀû¹®ÀÇ
KE.MLB50.3N Balance, analyzer moisture, 1mg-50g, 1/Ea. °ßÀû°¡ °ßÀû¹®ÀÇ
KE.RH.A02 Filtet, round fiberglass, 100/Pk. °ßÀû°¡ °ßÀû¹®ÀÇ
KE.YKB.01 Balance printer, for all balances, 1/Ea. °ßÀû°¡ °ßÀû¹®ÀÇ
Äü
¿À´Ãº»»óǰ
Àå¹Ù±¸´Ï
top